The SN75LBC184 and SN65LBC184 are differ-ential data line transceivers in the trade- standard footprint of the SN75176 with built-in protection against high-energy noise transients.This featureprovides a substantial increase in reliability for better immunity to noise transients coupled to thedatacable over most existing devices.Use of these circuits provides a reliable low-cost direct-coupled (withnoisolation transfomer) data line interface without requiring any external components.
The SN75LBC184 and SN65LBC184 can with-stand overvoltage transients of 400-Wpeak (typical). The conventional combination wave called out in IEC 61000-4-5 simulates the overvoltage transient and models a unidirectional surge caused by overvoltages from switching and secondary lightningtransients. A biexponential function defined by separate rise and fall times for voltage and current simulatesthe combination wave.The standard 1.2 μs/50μs combination waveform is shown in Figure 1andinthe test description in Figure 15.
The device also includes additional desirable features for party-linedata buses in electricallynoisy environment applications including industrial process control.The differential-driver designincorporates slew-rate-controlled outputs sufficient to transmit data up to 250 kbps.Slew-ratecontrol allows longer unterminated cable runs and longer stub lengths from the main backbone than possiblewithuncontrolled and faster voltage transitions.A unique receiver design provides a fail-safe output of ahighlevel when the inputs are left floating(open circuit).
The SN75LBC184 and SN65LBC184 receiver alsoincludes a high input resistance equivalent to one-fourth unit load allowing connection of up to 128similar devices on the bus. The SN75LBC184 is characterized for operation from 0℃ to 70℃.The SN65LBC184 is characterizedfrom-40℃to 85℃.
FEATURES
Integrated Transient Voltage Suppression
ESD Protection for Bus Terminals Exceeds: ±30 kV IEC 61000-4-2,Contact Discharge ±15 kV IEC 61000-4-2,Air-Gap Discharge ±15 kV EIA/JEDEC Human Body Model
Circuit Damage Protection of 400-W Peak (Typical)Per IEC 61000-4-5
Controlled Driver Output-Voltage Slew Rates Allow Longer Cable Stub Lengths
250-kbps in Electrically Noisy Environments Open-Circuit Fail-Safe Receiver Design
1/4 Unit Load Allows for 128Devices Connected on Bus
Thermal Shutdown Protection
Power-Up/-Down Glitch Protection
Each Transceiver Meets or Exceeds the Requirements of TIA/ElA-485 (RS-485)and ISO/IEC 8482:1993(E)Standards
Low Disabled Supply Current 300 μA Max
Pin Compatible With SN75176
Applications: - Industrial Networks - Utility Meters - Motor Contro

TEL:137 5117 9101
Emailhttps://www.hsesf.net